Home > Industrial Equipment & Components > Power & Generating Sets > Wind Generator > Inquiry about Small Francis turbine-generator set for inline application
Inquiry about Small Francis turbine-generator set for inline application NEW
Posted at: 2026-10-23 12:50
RFQ Information
We are New Life Corporation, an agricultural company in Tabacundo, Ecuador. We are looking for small Francis turbine-generator sets to recover energy at the pressure reducing valves of our irrigation pipeline. The application is in-line, meaning the turbine must discharge back into a pressurized pipe, not an open tailrace.
Site data (per PRV):
- Pipe: PVC, 355 mm OD, PN 12.5 (1.25 MPa)
- Flow: min 110 L/s, max 135 L/s (design approx. 122 L/s)
- Inlet pressure: 7 bar (approx. 70 m)
- Required outlet pressure: 2.5 bar (approx. 25 m), must be held constant
- Net head available: approx. 45 m
- Expected output: approx. 40–56 kW per unit
- Operation: 19 irrigation shifts per week, 2.5 hours each (daily start/stop)
- Quantity: 6 PRVs with similar conditions. Please quote for 3 units and 6 units.
Mandatory requirements:
1. Pressurized outlet (back-pressure 2.5 bar); casing, draft section and valves rated PN16.
2. Governor/control system that keeps downstream pressure constant and handles daily start/stop cycles.
Please provide your quotation and technical proposal based on these conditions.
| Product Name | Quantity | Target Price | Payment Terms | Attachment |
|---|---|---|---|---|
| Small Francis turbine-generator set for inline application | Not specified | -- | -- | -- |
You May Also Like
-
Inquiry about GE Speedtronic Mark V and EX2100 Turbine Control BoardsDate Posted: 2026-10-18
United States
Smart Trading Tips
The information displayed above is provided by buyers. We strongly recommend verifying the authenticity, accuracy, and qualifications of the buyer before engaging in any transactions to mitigate potential risks.