Hot Sell CE Medical Oxygen Regulator DY-C4
Specifications
Input pressurs:15mpa
Output Pressure:0.2mpa-0.3mpa
Fowmete Control Range:1L/Min-15L/min
Safety Valve:0.3mpa-0.05mpa
More details
1.All series have passed and CE certificate
2.The main part uses the goodness brass and cut with precision digitally controlled lathe
4.Integrated casting flowmeter
5.Flow tube ,wet cup of high-pressure sterillized Humidification body to meet European standards for B-level disinefection .
6.The maximunm temperature of 121 degree pressure 0.142mpa
How to use
1. Open the valve of oxygen cylinder after connect the screw nut of air intake closely.
2. Connect the oxygen pipe to the oxygen outlet firmly.
3. Demount the humidifying cup(anti clock wise rotation), put some distilled water in (purified water or plain boiled water can also take place), the water quantity should be between the bottom and top tick mark, then tighten up the bottle cap to the humidifying cup(clockwise rotation).
4. Rotate the flow regulating valve to the rate you need (anti clockwise to up, clockwise to down, till to close), then put it to nose to use.
5. Close the valve of oxygen cylinder firstly while not using, then close the flow regulating valve until the pointer of oxygen manometer return to zero.
Quality guarantee period
We will fix or change the oxygen inhalator within a half and a year after the day of living the company when it can't proper functioning, it should be under the condition of obeying the rule of storage and using.
Specification
1. Forbid to use the Buoy Type Oxygen Regulator to take oxygen atomization treatment.
2. Forbid to dismount by yourself.
Attention
1.Make sure there is on ash on the connector and check the screw thread, then install the inhalator
2.Make sure the flow meter is vertical to the floor and flow regulating valre is closed,then Open the valve of oxygen cylinder slowly,regulate the flow after the high pressure gavge shows the pressure of the oxygen cylinder .
3.No drestic shock,for away with the corrsive substance and no oil stain .
4.The set screw of the safety valve can't be rotated at randon,non-professional people are forbidden to dismount .
Condition for strage
shoule be kept in the environmen whose humidity is less than 90% no corrosive gas and drafty.
Send Inquiry to This Supplier
You May Also Like
-
Static Pass Box(passing Box & Equipment for Clean Room)NegotiableMOQ: 1
-
High Quality Hydraulic Obstetric Delivery Surgical Table Manual Birthing ChildbedNegotiableMOQ: 1 Set
-
Quick Release Basket Ambulance Stretcher Band/strap/beltNegotiableMOQ: 300 Pieces
-
26 Pcs First Aid Kit,Car Emergency Kit,auto Safety KitNegotiableMOQ: 1000 Sets
-
First AidUS$ 0.5 - 0.5MOQ: 5000 Pieces
-
Emergency Blanket/Emergency Membrane/Rescue BlanketsNegotiableMOQ: 1000 Pieces
-
Plastic Aid Board by RotomouldedNegotiableMOQ: 1
-
Expert Supplier of Suction MachineUS$ 2,300 - 6,900MOQ: 1 Set
-
Shoulder Joint-functional Model Half Life SizeNegotiableMOQ: 50 Pieces
-
(KL600-II) Integral Single Head Wall Mounted OT Lights Led ot Lights Medical ot LightsUS$ 1,400 - 1,600MOQ: 1 Set