Home > Health & Medicine > Medical Equipment > Ventilator > Multipara Monitor/Multipara Patient Monitor With ETCO2 Good Price

Multipara Monitor/Multipara Patient Monitor With ETCO2 Good Price

Multipara Monitor/Multipara Patient Monitor With ETCO2 Good Price photo-1
US$ 400 - 600 MOQ: 5 Units
Key Specifications
Get Latest Price
Type:
Other, First-Aid Devices, Patient Monitor/multipara monitor
Brand Name:
JoyMed Or OEM
Model Number:
JM-9005A/B or OEM
Payment & Shipping
Payment Methods:
Port of Shipment:
shanghai
Delivery Detail:
Delivery time depends on order quantity.
Type Other, First-Aid Devices, Patient Monitor/multipara monitor
Brand Name JoyMed Or OEM
Model Number JM-9005A/B or OEM
Place of Origin Jiangsu, China

JM-9005 A/B   Mulit-Parameter Patient Monitor/Multipara Monitor

Specifications

12.1''high resolution color TFT display

96 hours trend graphic data, 12-lead ECG analysis

Arrhythmia and S-T segment analysis

Anti-defibrillation, Anti-high frequency electrotome

Multi-language,easy operate,durable and stable

Calculation function of drug concentration  

     drug titration and hemodynamic status   

Wired or wireless network   

Three-level Audible and visible alarm,events recallable

     Nurse Call function

AC/DC power supply, built-in high rechargeable capacity battery  

Built in high speed thermoprinter with 12.5, 25, 50mm/sec

Recharge of the battery automatically at connection of the

device to the circuit and automatic switching to battery at circuit

failure without loss of all data and parameters

Chinese, English and Russian language interface

Standard configuration: Battery, ECG,RESP,NIBP,SPO2,PR,TEMP

Optional function:  IBP,EtCO2

Concentration of anaesthesiological gases(optional)

Specification:

Dimension:                   272(H) X 327(W) X 145(D) (mm)

Weight:                         6.5Kgs (with battery)

Resolution:                   800x600

Display: Amount of waveforms in display 5

              Amount of numerical parameters displayed on display

              not less than 5

Power Supply: 220V±101%, 50Hz, power cable with euro plug

ECG

Measuring range:         Adult   0~300bpm

                                     Neonate and pediatric   0~350bpm

Band width:                  0.05Hz~100Hz

Accuracy:                     ±1%

Lead Type:                    5-lead and 3-lead selectable

Lead selection:             standard I,II,III; augmented limb lead

                                     aVR, aVL, aVF;Chest lead V1~V6

Resolution:                   1 bpm

Trend monitoring time:no less than 96 hours

ST-Segment analysis:  -2.0 mV ~2.0mV; auto

Arrhythmia analysis:    13 kinds of Arrhythmia analysis

                                     Recognition of

                                     cardiostimulator impulses

Scanning speed:          12.5, 25, 50mm/Second

Gain selection:             x1/2, x1, x2; auto

Protection:                   Withstand 4000 VAC/ 50Hz voltage

                                     Voltage in isolation against

                                     Defibrillation and electrosurgical

                                     interference

ECG cable :                   adults, pediatric and neonate

Alarm Range:               15-350 bpm

ARR Alarm:                   Audible and visible alarm,

                                     events recallable

Channels:                     Five

                                     Manual choice of amplification

NIBP

Method:                        Automatic Oscillometric

Operation Model:          manual, automatic, continuous

Auto measurement

time interval:                Adjustable 1 /2 /3/4

                                     /5/10/15/30/60/90/120/240/480   Min.

Measuring Unit:            mmHg /kPa selectable

Measurement types:     Systolic, Diastolic, Mean

Measuring Range:         Adult:     10~270mmHg; optional   0-300mmhg

                                     Pediatric:10~200mmHg

                                     Neonate: 10~135mmHg

sp;     pediatric   10~200mmHg

                             neonate   10-135mmHg

Cuff pressure range: 0~320mmHg

Cuff type: adult cuff (standard)

                 pediatric and neonatal cuff (optional)

Cuff inflation time: < 10 seconds

Cuff deflation time: <20 seconds  

Alarm: the maximum and minimum value can be set freely according to your need which will be stored by system automatically.

TEMP

Measuring range: 0~ 50 oC ( 32~122oF  )

Probe Type: body temperature probe (standard)

                    esophageal temperature probe and Rectal Temperature probe

Resolution: 0.1oC

Accuracy: ±0.1oC (without probe)

Alarm: the maximum and minimum value can be set freely according to your need which will be stored by system automatically.

SpO2

Display: SpO2 value display, PR chart display and PR waveform display

SpO2  measuring range: 0~100% for adults, pediatrics and neonates

Resolution: 1%

Accuracy: ±1% ( 70%~100%)

                ±2% (0%~69%)

PR measuring range: 0~255 bpm

PR accuracy: ±1 bpm

Sensor Type: adult finger clip SpO2 sensor (standard)

                      pediatric finger clip SpO2 sensor and neonatal wrap SpO2 sensor (optional)

multipara monitor/Multipara Patient Monitor with ETCO2 good pricemultipara monitor/Multipara Patient Monitor with ETCO2 good pricemultipara monitor/Multipara Patient Monitor with ETCO2 good pricemultipara monitor/Multipara Patient Monitor with ETCO2 good pricemultipara monitor/Multipara Patient Monitor with ETCO2 good price

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2016
Factory Size
1,000-3,000 square meters
Total Employees
51 - 100 People