18KW Capacitor Switching Contactor
12Amps 18KW Capacitor Switching Contactor
Model: CJ19-25
Reversing Contactors (Magnetic Contactor) provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instruments and equipments against overload currents by using thermal relays, for capacitor switching contactor. While switching on a capacitive circuit, a high frequency (1...15Hz) and large transient current peaks are produced. Switching of capacitor for a single or one of the capacitor banks are different from each other. Step by step "switching on" operation is more difficult for contactor than capacitor bank. Because during this operation for capacitor bank, compensated current occurs. For this reason selecting of suitable contactors the compensating current must be take into consideration for 50kVAR and above, and for less than 50kVAR can be omitted.
- As it is known, when the capacitor starts to operate, they cause a high frequency between 1~15kHz. And a current that is 180time higher than rated current for very short time period. Shock inductance is to be fixed to each phase to limit this current. But practically this type of operation is difficult. That's why capacitor switching contactors are used and for this reason the life-time of contactors increase 100% in comparision with normal contactor.
- While Switching on a capacitive circuit, a high frequency (1...15kHz) and large transient current Peaks are produced. Switching of capacitor for a single or one of the capacitor banks are different from each other. Step by step "switching on" operation is more difficult for contactor than capacitor bank. Because during this operation for capacitor bank, compensated current occurs. For this reason selecting of a suitable contactors the compensating current must be take into consideration for 50kVAr and above, and for less than 50kVAr can be ommitted.
- Operating Principle: When coil of contactor is energized, first contact of passing block is closed, starting current of contactor is passed through this contact, approximately after 3-5 ms contacts of passing blocks are opened and rated current of contactor is carried on main contacts.
- Magnetic Contactor should have the high current value without being exposed to and damaged or boiling. This belongs to the quality of contactor. (Contact surface quality and weld technology) Especially at AC-3 and capacitor command, selectivity of contactor is very important.
- Current which passes through the contacts causes warming when the contactor is closed. This warming is limited with the standards. For IEC60947-4-1 when continual thermal current (Ith) is passed though the main contacts, maximum increasing temperature should not exceed 65k.
- While the contactor is cutting the current, electrical arc occurs between the seperated contacts. Arc is the result of the thermal impression of electron and ion current which broke off the contact material. Temperature of the arc reaches to thousands of degrees and this temperature is too high for metals and insulators which are used at contact making and cutting cells. Therefore, arc should end as soon as possible. For this reason separators are used inside of contactors.
- Rated Current.............................................................12A
- Control Capacity.........................................................18KW
- No. of Pole...................................................................3-POLE
- Rated Operational Voltage.........................................690V AC
- Rated Insulated Voltage.............................................690V AC
- Frequency....................................................................50/60Hz
- Standards................................................................... IEC60947-4-1
- IP / NEMA Rating.........................................................IP20
- Connection..................................................................Screw + Cable Lug
- Working Temperature................................................-20℃ ~ +80℃
- Mechanical Life.......................................................... 20,000times
- Sample Service...........................................................Pay to Provide
- Quality Assurance......................................................24 months
- Item Condition.............................................................Brand-New
| Item | Control Capacity | Rated Current | Case Qty. |
| Model | (KW) | (A) | (Pcs.) |
| CJ19-25 | 18 | 12 | 40 |
| CJ19-32 | 23 | 18 | 32 |
| CJ19-43 | 29 | 20 | 32 |
| CJ19-63 | 43 | 30 | 20 |
| CJ19-95 | 63 | 40 | 20 |
NB: Please mention the coil voltage when ordering. Our standard coil voltages are 24V, 36V, 110V, 220V, 380V, 415V, other else upon request.

Send Inquiry to This Supplier
You May Also Like
-
ABB A145-30-11 A1453011 220VACNegotiableMOQ: 1 Piece
-
AC ContactorNegotiableMOQ: 2500 Pieces
-
Air Coil Circuit Electric Rating ac Magnetic Contactor PriceNegotiableMOQ: 1
-
FC-1UL ContactorNegotiableMOQ: 1 Piece
-
ContactorUS$ 50 - 600MOQ: 5 Pieces
-
STEEL DIN RAIL SERIES (TH35/7.5)US$ 0.42 - 0.5MOQ: 10000 Meters
-
2015 China Factory CJX9 Series AC Magnetic Contactor PriceUS$ 1 - 100MOQ: 10 Units
-
TNC Female Square Panel MountingUS$ 0.1 - 10MOQ: 1 Piece
-
ContactorUS$ 50 - 600MOQ: 5 Pieces
-
AD Magnetic StarterNegotiableMOQ: 500 Pieces