0.6/1kV XLPE Insulated Electrical Power Cable,19/33kV Underground Power Cable,26/35kV Medium Voltage Power Supply Cable
Specifications
0.6/1kV XLPE insulated electrical power cable,19/33kV underground power cable,26/35kV medium voltage power supply cable
0.6/1kV XLPE insulated electrical power cable,19/33kV underground power cable,26/35kV medium voltage power supply cable
Detailed Product Description
1 IEC, ASTM, DIN, BS standard
2 ISO,CCC,CB certification
3 Response within 12 hours
4 Free Sample
5 Factory direct sale
1 Application: It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Power cables for power networks, underground, outdoors and in cable ducting.
Standards: BS6622, BS EN/IEC 60228
Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Conductor screen: Semi-conducting material
Insulation: XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
Insulation Screen: Semi-conducting material
Metallic Screen: Individual and overall copper tape screen to BS6622
Filler: PETP (Polyethylene Terephthalate) fibres
Separator: Binding tape
Bedding: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Armouring:
Single Core: Aluminium Wire Armoured (AWA)
MultiCore: Steel Wire Armoured (SWA)
Sheath: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Colour: Red or Black
2 Using features:
1. Rated voltage: Uo/U:3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
2. No. of core: Single core or three cores.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250oC.
4. D.C. resistance of the conductor complies with the stipulations of 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit.
7. Working Frequency Voltage Test: 3.5Uo/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.


Note:
The single core armoured cables are used for D.C. system only. If used for A.C. system, the magnetic isolation should be applied on the steel armoire wires of non-magnetical materials should be used.
0.6/1kV XLPE insulated electrical power cable,19/33kV underground power cable,26/35kV medium voltage power supply cable
Send Inquiry to This Supplier
You May Also Like
-
Bulk Electrical Wire Low EccentricityUS$ 1 - 10000MOQ: 1 Piece
-
Sick YF8U14-050VA3XLEAX - Sensor/actuator CableNegotiableMOQ: 1 Piece
-
Wire and CableNegotiableMOQ: 2000 Rolls
-
Fpc Cable Ffc Cable EDP Cable LVDS Harness VBYONE Harness Coaxial CableUS$ 7 - 10MOQ: 100 Units
-
4/8/16/32CH Channels Multi Cable With Wheel/6 UTP Multipair CableUS$ 500 - 800MOQ: 10 Pieces
-
Enamelled Copper Magnet Wire 2.0mm Round Heavy Duty ApplicationsUS$ 4.89MOQ: 500 Kilograms
-
Fireproof CableNegotiableMOQ: 500 Meters
-
Water Proof Network Cable Lan Cable Cat5e UTP Ftp Cat5E Cat6US$ 0.1 - 0.7MOQ: 10 Kilometers
-
Multicore Mineral Insulated Heating Cable for Customized Heating SolutionsNegotiableMOQ: 500 Meters
-
Factory Price High Quality 1mm 1.5mm 2mm 2.5mm 4mm Aluminum Enamelled Winding Electrical WireUS$ 3.23 - 3.96MOQ: 1000 Kilograms