US$ 0.31 - 11.56 MOQ: 300 Meters
Key Specifications
Get Latest Price
Place of Origin:
Henan, China
Brand Name:
BEI HOU
Model Number:
ACSR conductor
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai Tianjin Qingdao or as per request
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Henan, China
Brand Name BEI HOU
Model Number ACSR conductor
Conductor Material Other, Aluminum and conductor
Insulation Material Other, bare
Jacket Other, none
Number of Conductors Multi-core
Application Overhead power distribution line

acsr bare conductor price types of acsr conductors osprey conductor

 

Product Description

 

 The Specifications of  ACSR conductor 

(1) all aluminium conductor (AAC)

(2) all aluminimum alloy conductor(AAAC)

(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)

(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)

(7)aluminimum conductor aluminimum alloy reinforced(ACAR)

 

Elative manufacturing standards

Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.

1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.

2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM

(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

 

The application of  aluminium conductor

Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

 

The construction of aluminium conductor 

Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; "aluminized" aluminum coated (AZ); or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

 

 

Notes

Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.

Current ratings are based on 75centigrade conductor temperature, 25centigrade ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

ACSR

IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182,JIS C3110

AAC

IEC61089, BS215 part1, ASTM B231, DIN48201, JIS C3109, CSA C49

AAAC

IEC61089, BS 3242, ASTM B399, BS EN50183, DIN48201

ACS

ASTM B505, ASTM B416, DIN 48201

ACAR

ASTM B524, IEC 61089

AACSR

ASTM B711, DIN 48206, IEC 61089

We have attained ISO9001 & ISO14001 certificates.  

 

 Specification: Aluminum Conductor Steel Reinforced

Standard: ASTMB232, DIN48204, BS215 PART2, IEC61089, IEC209, IEC888, IEC889, EN50182

Application: Aluminum conductor steel wire reinforced wire used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. 

Package:  Wooden Drum Package or Iron-wooden drum


Technical Part 

477 mcm acsr conductor

BS215 PART2
Code
name
Cross
section
No.of wires Wire daimeter Diameter Mass per
unit length
Rated
strength
Maximum
DC resistance
at 20°C
Al Steel Total Al Steel Core Cond.
mm2 mm2 mm2 Al Steel mm mm mm mm kg/km kN ohm/km
MOLE 10.6 1.77 12.4 6 1 1.50 1.50 1.50 4.50 42.8 4.14 2.7027
SQUIRREL 21.0 3.50 24.5 6 1 2.11 2.11 2.11 6.33 84.7 7.87 1.3659
GOPHEL 26.2 4.37 30.6 6 1 2.36 2.36 2.36 7.08 106.0 9.58 1.0919
WEASEL 31.6 5.27 36.9 6 1 2.59 2.59 2.59 7.77 127.6 11.38 0.9065
FOX 36.7 6.11 42.8 6 1 2.79 2.79 2.79 8.37 148.1 13.21 0.7812
FERRET 42.4 7.07 49.5 6 1 3.00 3.00 3.00 9.00 171.2 15.27 0.6757
RABBIT 52.9 8.81 61.7 6 1 3.35 3.35 3.35 10.1 213.5 18.42 0.5419
MINIK 63.1 10.5 73.6 6 1 3.66 3.66 3.66 11.0 254.9 21.67 0.4540
SKUNK 63.2 36.9 100.1 12 7 2.59 2.59 7.77 13.0 463.0 52.79 0.4568
BEAVER 75.0 12.5 87.5 6 1 3.99 3.99 3.99 12.0 302.9 25.76 0.3820
HORSE 73.4 42.8 116.2 12 7 2.79 2.79 8.37 14.0 537.3 61.26 0.3936
RACOON 78.8 13.1 92.0 6 1 4.09 4.09 4.09 12.3 318.3 27.06 0.3635
OTTER 83.9 14.0 97.9 6 1 4.22 4.22 4.22 12.7 338.8 28.81 0.3415
CAT 95.4 15.9 111.3 6 1 4.50 4.50 4.50 13.5 385.3 32.76 0.3003
HARE 105.0 17.5 122.5 6 1 4.72 4.72 4.72 14.2 423.8 36.04 0.2730
DOG 105.0 13.6 118.5 6 7 4.72 1.57 4.71 14.2 394.0 32.65 0.2733
COYOTE 131.7 20.1 151.8 26 7 2.54 1.91 5.73 15.9 520.7 45.86 0.2192
COUGAR 131.5 7.31 138.8 18 1 3.05 3.05 3.05 15.3 418.8 29.74 0.2188
TIGER 131.2 30.6 161.9 30 7 2.36 2.36 7.08 16.5 602.2 57.87 0.2202
WOLF 158.1 36.9 194.9 30 7 2.59 2.59 7.77 18.1 725.3 68.91 0.1829
DINGO 158.7 8.81 167.5 18 1 3.35 3.35 3.35 16.8 505.2 35.87 0.1814
LYNX 183.4 42.8 226.2 30 7 2.79 2.79 8.37 19.5 841.6 79.97 0.1576
CARACAL 184.2 10.2 194.5 18 1 3.61 3.61 3.61 18.1 586.7 40.74 0.1562
PANTHER 212.1 49.5 261.5 30 7 3.00 3.00 9.00 21.0 973.1 92.46 0.1363
JAGUAR 210.6 11.7 222.3 18 1 3.86 3.86 3.86 19.3 670.8 46.57 0.1366
LION 238.3 55.6 293.9 30 7 3.18 3.18 9.54 22.3 1093.4 100.47 0.1213
BEAR 264.4 61.7 326.1 30 7 3.35 3.35 10.1 23.5 1213.4 111.50 0.1093
GOAT 324.3 75.7 400.0 30 7 3.71 3.71 11.1 26.0 1488.2 135.13 0.0891
SHEEP 375.1 87.5 462.6 30 7 3.99 3.99 12.0 27.9 1721.3 156.30 0.0771
ANTELOPE 374.1 48.5 422.6 54 7 2.97 2.97 8.91 26.7 1413.8 118.88 0.0773
BISON 381.7 49.5 431.2 54 7 3.00 3.00 9.00 27.0 1442.5 121.30 0.0758
DEER 429.6 100.2 529.8 30 7 4.27 4.27 12.8 29.9 1971.4 179.00 0.0673
ZEBRA 428.9 55.6 484.5 54 7 3.18 3.18 9.54 28.6 1620.8 131.92 0.0674
ELK 477.1 111.3 588.5 30 7 4.50 4.50 13.5 31.5 2189.5 198.80 0.0606
CAMEL 476.0 61.7 537.7 54 7 3.35 3.35 10.1 30.2 1798.8 146.40 0.0608
MOOSE 528.5 68.5 597.0 54 7 3.53 3.53 10.6 31.8 1997.3 159.92 0.0547

 

acsr bare conductor price types of acsr conductors osprey conductor

 

acsr bare conductor price types of acsr conductors osprey conductor

 

acsr bare conductor price types of acsr conductors osprey conductor

 

Models for ACSR

Model

Name

GB1179-83

GB1179-2008

LJ

JL

All Aluminum Conductor(AAC)

LGJ

JL/G1A JL/G2A JL/G1B JL/G2B JL/G3A

Aluminum Conductor Steel Reinforced (ACSR)

LGJF

JL/G1AF JL/G2AF JL/G3AF

Anti-corrosive ACSR

 

Technical data for ACSR

Nominal

Aluminium

Area

(mm2)

 

 

Strand and Wire

Dia

(No./mm)

Calculated

Area

(mm2)

Approx

Overall

Dia

(mm)

Approx

Weight

(kg/km)

Calculated  Breaking Load Min

(KN)

Calculated

D.C Resistance At 200C

(ohm/km)

Code

Word

Al

St

Al

St

20

6/2.11

1/2.11

20.98

3.50

6.33

84.85

7.90

1.368

Squirrel

25

6/2.36

1/2.36

26.24

4.37

7.08

106.10

9.61

1.0930

Gopher

30

6/2.59

1/2.59

31.61

5.27

7.77

127.80

11.45

0.9077

Weasel

40

6/3.00

1/3.00

42.21

7.07

9.00

171.50

15.20

0.6766

Ferret

50

6/3.35

1/3.35

52.88

8.81

10.05

213.80

18.35

0.5426

Rabbit

60

6/3.66

1/3.66

63.12

10.52

10.98

255.30

21.77

0.4546

Mint

60

12/2.59

7/2.59

63.23

36.88

12.95

463.60

52.94

0.4566

Skunk

70

12/2.79

7/2.79

73.37

42.80

13.95

538.10

61.20

0.3936

Horse

70

6/4.09

1/4.09

78.84

13.14

12.27

318.90

27.05

0.3639

Raccoon

100

6/4.72

7/1.57

105.00

13.55

14.15

394.30

32.70

0.2733

Dog

150

30/2.59

7/2.59

158.10

36.88

18.13

725.70

69.20

0.1828

Wolf

150

18/3.35

1/3.35

158.70

8.81

16.75

505.70

35.70

0.1815

Dingo

175

30/2.79

7/2.79

183.40

42.80

19.53

842.40

79.80

0.1576

Lynx

175

18/3.61

1/3.61

184.30

10.24

18.05

587.60

41.10

0.1563

Caraca

200

30/3.00

7/3.00

212.10

49.48

21.00

973.80

92.25

0.1363

Panther

200

18/3.86

1/3.86

210.60

11.70

19.30

671.40

46.55

0.1367

Jaguar

250

30/3.35

7/3.35

264.40

61.70

23.45

1214.00

111.40

0.1093

Bea

300

30/3.71

7/3.71

324.30

75.67

25.97

1489.00

135.70

0.08912

Goat

300

18/4.78

7/1.68

323.10

15.52

24.16

1012.00

69.64

0.08914

Batang

350

54/3.00

7/3.00

381.70

49.48

27.00

1443.00

120.70

0.07572

Bison

400

54/3.18

7/3.18

428.90

55.59

28.62

1622.00

131.90

0.06741

Zebra

450

30/4.50

57/4.50

477.00

111.30

31.50

2190.00

198.30

0.06057

Elk

450

54/3.35

7/3.35

476.00

61.70

30.15

1800.00

146.20

0.06074

Camel

500

54/3.35

7/3.35

528.50

68.50

31.77

1998.00

161.00

0.05470

Moose

 

 

Packaging & Shipping

 In rolls, wooden drums, steel drums or steel-wooden drums or as per request.

 acsr bare conductor price types of acsr conductors osprey conductor

 

acsr bare conductor price types of acsr conductors osprey conductor

 

 

 

Our Services

 

1.20 years professional cable manufacture experience since 1996.

2. Competitive price and standard quality.

3.Standardized quality management under ISO9001:2008

4.OEM (Original Equipment Manufacture)acceptable

5.Free sample are available.

6.24 hours online service,quickly response to your questions.

acsr bare conductor price types of acsr conductors osprey conductor

FAQ

 Q1: Are you a factory or trading company?  

A: Zhengzhou Yuanda Cable Co. Ltd (Headquarter) is a large manufacture in the middle of China with 1, 000 staff.

 

Q2: Where is your company? How can I visit there?  
A: Our Company is located in Room 2304, Building 1, No. 157 Fuyuan Road, Jinshui District, Zhengzhou, Henan, China. Visitors can come to our company by train to Zhengzhou station or by plane to Zhengzhou Airport.

 

Q3:How can I get samples? 
A: Free Samples will be sent to customers by economic international express if available, Freight Charge will be normally on buyer’s account.                   


Q4:How does your factory do regarding quality control? 
A: Zhengzhou Yuanda Cable Co., Ltd. has passed ISO 9001 and ISO 14001, CCC certificates. Each products must be went through professional test. We promise to provide qualified cables.

 

Q5: Which payment terms do you accept?

A: The payment term varies with different price and total value of each contract.

Common terms are as follows:

a.100% TT advance for small amount orders.

b. T/T 30% deposit, and balance payment negotiable accordingly.

Other payment terms also can be available by both sides agreement.

 

Q6: Have you ever exported cables to other countries?

A: Yuanda Cables have been supplied to many countries especially in Middle East,Middle Asia,South America,Southeast Asia countries and regions etc.

 

Q7: What is your MOQ?

A: MOQ varies as per the cable type.Normally 500 meters for big diameter cables. Please feel free to contact us directly for detail information if you have any specific requirements.

Company Information

 

 

 acsr bare conductor price types of acsr conductors osprey conductor

Established: 1996.
Factory area: 60,000 square meters, and 40,000 square meters for building area.

Fixed assets: USD 200 million.

No.of stuff : over 1,000.

Annual output: 100,000 tons.

Certificates: IEC, ISO 9001, ISO 14001, CCC, BV, JIS, UL, BS, OHSAS 18001, TUV, CE

CB and so on.

Workshops: rubber cable workshops, conductor workshop, XLPE cable workshop, electric cable workshop, special cable workshop, and workshops for telephone wire , TV lines and parvicostellae.

 acsr bare conductor price types of acsr conductors osprey conductor

 

Our Principles

1)Quality first, customer first, safety first

2)Better service, faster delivery

3)Mutual benefit and cooperation

4)Honesty and profession

 

Other cables

 acsr bare conductor price types of acsr conductors osprey conductor

 

Trade Shows

 acsr bare conductor price types of acsr conductors osprey conductor

Certificates

 acsr bare conductor price types of acsr conductors osprey conductor

 

acsr bare conductor price types of acsr conductors osprey conductor

 

 

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2014
Factory Size
50,000-100,000 square meters
Total Employees
301 - 500 People