Home > Electrical & Electronics > Electrical Control System > Honeywell CC-PAIH01 51405038-175 Analog Input Module

Honeywell CC-PAIH01 51405038-175 Analog Input Module

Honeywell CC-PAIH01 51405038-175 Analog Input Module photo-1
Honeywell CC-PAIH01 51405038-175 Analog Input Module photo-2
Honeywell CC-PAIH01 51405038-175 Analog Input Module photo-3
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Material:
Other, Honeywell
Condition:
Other, Global universal model
Task:
Other, Global universal model
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Material Other, Honeywell
Condition Other, Global universal model
Task Other, Global universal model
Mathematical Model Other, Global universal model
Signal Other, Global universal model
Customized Other, Global universal model
Structure Other, Global universal model
Dimensions 125mm x 100mm x 35mm
Weight 0.4kg
Honeywell CC-PAIH01
Functional Features
  • Signal Input and Processing
    It can receive current or voltage inputs, with input ranges such as 4-20mA or 0-10Vdc, supporting 16-channel high-level analog inputs. Only channels 13 to 16 support differential input. With 16-bit resolution, it accurately collects analog signals to achieve high-precision data acquisition.
  • Communication Functions
    Supporting the HART communication protocol, it enables seamless data exchange with field devices for remote monitoring and diagnosis. It also is compatible with Modbus and Canopen protocols to ensure interoperability with a wide range of industrial automation systems.
  • Self-Diagnosis and Protection Functions
    Equipped with extensive self-diagnosis functions, it can monitor its working status in real time, detect faults such as open wires, provide process variable protection through relevant diagnostic functions, and has a non-flammable field power supply to enhance safety in hazardous environments.
Technical Parameters
  • Power Requirements
    Usually powered by a 24Vdc power supply.
  • Sampling Rate and Accuracy
    • Sampling rate: 100Hz.

    • Accuracy: ±0.25% of full scale.

    • Repeatability: ±0.05% of full scale.

  • Working Environment
    • Operating temperature range: -40°C to +85°C.

    • Humidity range: 5% to 95% RH (non-condensing).

    • Protection level: IP20.

  • Dimensions and Weight
    • Dimensions: approximately 125mm x 100mm x 35mm.

    • Weight: approximately 0.4kg.

CC-PAIH01 51405038-175 (3)

CC-PAIH01 51405038-175 (1)

CC-PAIH01 51405038-175 (2)

Working Principle of CC-PAIH01I. Hardware Architecture and Signal Interaction Basis
  • Core Processing Unit
    It may be equipped with an industrial-grade microprocessor or controller as the core for data processing and logical operations, supporting a real-time operating system (RTOS) to ensure fast response and stability of control tasks.
    It connects each functional module (such as communication interfaces, I/O modules, etc.) through the motherboard or integrated circuits to achieve collaborative work of hardware resources.
  • Input/Output (I/O) Modules
    • Analog Input (AI): It may support standard industrial signal inputs such as 4-20mA and 0-10V, used to collect real-time data from sensors (such as temperature, pressure, and flow sensors), and converts analog signals into digital signals through analog-to-digital conversion (A/D conversion).

    • Analog Output (AO): It outputs analog signals through digital-to-analog conversion (D/A conversion) to control actuators (such as control valves and frequency converters) to achieve continuous adjustment of industrial processes.

    • Digital Input/Output (DI/DO): It supports the input and output of switching signals (such as device start/stop status and alarm signals), used to control switching devices such as relays and indicator lights.

  • Communication Interfaces
    It may integrate interfaces such as Ethernet (e.g., 10/100Mbps), RS-485, and RS-232, supporting industrial communication protocols such as Modbus, BACnet, and OPC UA to interact data with upper computers (such as SCADA systems), other controllers, or intelligent devices for remote monitoring and system integration.
II. Data Collection and Processing Logic
  • Real-Time Data Collection
    It periodically collects analog signals from field devices (such as voltage signals from temperature sensors and current signals from flowmeters) through AI interfaces, converts them into digital quantities via A/D converters, and stores them in the controller's memory.
    DI interfaces monitor digital signals (such as valve switch status and motor start/stop signals) in real time and record device status in binary form.
  • Signal Processing and Operation
    It preprocesses the collected data, such as filtering, linearization, and calibration, to eliminate noise interference and ensure data accuracy.
    It analyzes the data based on preset algorithms (such as PID control, logical operations, and threshold judgment). For example:
    • When the input of the temperature sensor exceeds the set threshold, it triggers the alarm logic or automatically adjusts the cooling equipment.

    • According to the deviation between the flow data and the target value, it calculates the output signal through the PID algorithm to control the valve opening.

Application Fields
  • Industrial Automation
    In various industrial production processes, it is used to collect analog signals such as temperature, pressure, and flow, providing accurate data support for automation control systems to achieve precise control and monitoring of production processes.
  • Petrochemical Industry
    It is suitable for high-precision monitoring and control of various process parameters in the petroleum and chemical industries, such as temperature and pressure monitoring of reactors and pipeline flow monitoring, to ensure the safety and stability of production processes.
  • Electric Power
    It can be applied to power systems such as power plants and substations to collect various analog signals of power equipment, such as voltage, current, power, and other parameters, to achieve real-time monitoring and automated control of the power system and ensure the reliability and stability of power supply.
  • Water Treatment
    In water treatment facilities such as sewage treatment plants and waterworks, it is used to monitor water quality parameters such as pH, dissolved oxygen, and turbidity, as well as control the operation of equipment such as water pumps and valves, to achieve automated control and optimization of the water treatment process.
  • Pharmaceuticals
    It meets the requirements for precise monitoring of environmental parameters and equipment status in the pharmaceutical production process, such as temperature and humidity monitoring in clean rooms and pressure and flow control of production equipment, to ensure that drug production complies with relevant quality standards and specifications.
Product Tags: CC-PAIH01 , CC-PAIH02 , 51405038-375

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Trading Company
Year Established
2014
Factory Size
1,000-3,000 square meters
Product Certifications