Home > Electrical & Electronics > Relay & Contactor > Relay > Bently Nevada 1900/65A-00-04-01-00-00 – General Purpose Equipment Monitor for Reliable Machinery Protection

Bently Nevada 1900/65A-00-04-01-00-00 – General Purpose Equipment Monitor for Reliable Machinery Protection

Bently Nevada 1900/65A-00-04-01-00-00 – General Purpose Equipment Monitor for Reliable Machinery Protection photo-1
Bently Nevada 1900/65A-00-04-01-00-00 – General Purpose Equipment Monitor for Reliable Machinery Protection photo-2
Bently Nevada 1900/65A-00-04-01-00-00 – General Purpose Equipment Monitor for Reliable Machinery Protection photo-3
US$ 216.00 ≥1 Blade
Key Specifications
Get Latest Price
I/O Number:
Bently Nevada 1900/65A-00-04-01-00-00
Place of Origin:
America
Communication Interface:
Modubus
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
I/O Number Bently Nevada 1900/65A-00-04-01-00-00
Place of Origin America
Communication Interface Modubus
Product name Variable frequency driver
Model Number Bently Nevada 1900/65A-00-04-01-00-00
Condition NEW
Warranty One Year
Package Original Packaging
HS Code 903289
Order Placement Process and Guarantees
  • Warranty: 365 days

  • Delivery: 1 week if in stock; no more than 1 month latest

  • Payment Terms: 50% advance; full payment before delivery

  • Express Options: FedEx, UPS, DHL

Key Features
  • Two dynamic channels – Typically configured for proximity probes or accelerometers to monitor vibration on balance-of-plant equipment.

  • Keyphasor®/tach input – Supports speed and phase reference, enabling 1× tracking and more meaningful alarms.

  • 4–20 mA outputs – Proportional outputs per channel for easy tie-in to PLCs/DCS; keeps operations teams informed without extra software.

  • Dual-level alarms (Alert/Danger) – Standard protection philosophy with configurable latching and time delays in many cases.

  • Relay outputs – Use as annunciation or for interlocks/trips on exceedance; simplifies protection design.

  • Modbus communications – Typically Modbus RTU over RS‑485 for status, values, and health—handy for remote supervision.

  • Compact installation – A space‑saving monitor that fits into crowded MCCs or local junction cabinets.

  • Configured for general-purpose assets – Suits pumps, fans, and blowers where continuous protection is desired without a full rack system.

Technical Specifications
Brand / Model Bently Nevada 1900/65A-00-04-01-00-00 (General Purpose Equipment Monitor)
HS Code 9032.89 (Automatic regulating or controlling instruments and apparatus)
Power Requirements 24 VDC nominal
Signal Inputs Two dynamic vibration channels (proximity or accelerometer); Keyphasor®/tach input
Signal Outputs 4–20 mA proportional outputs; alarm/trip relays (form C)
Communication Interfaces Modbus RTU (RS‑485)
Installation Method Compact cabinet mounting; commonly DIN‑rail in many panels
Application Fields

This monitor is typically specified for balance‑of‑plant rotating assets across:

  • Oil & Gas and Petrochemical – auxiliary pumps, blowers, air coolers

  • Power Generation – condensate/extraction pumps, ID/FD fans, cooling tower gearboxes

  • Water & Wastewater – high‑service pumps and aeration blowers

  • Pulp & Paper / Mining – process fans, slurry pumps, vacuum pumps

  • General Industry – HVAC chillers, compressors, and utility machinery

A maintenance lead from a midstream facility told us it “dropped nicely into our existing PLC cabinet, 4–20 mA into the DCS, and the relays tied straight into the trip logic—no drama, and we got legitimate alarm points rather than guesswork.”

D1F2A77952A7729F5FB225D562FE4249

Advantages & Value
  • Reliable protection – Dual-level alarms and hardwired relays reduce nuisance trips while still guarding the asset.

  • Easy integration – 4–20 mA and Modbus RTU mean fast commissioning into almost any PLC/DCS without special software.

  • Lower lifecycle cost – A compact monitor usually costs less than a full rack, and ongoing maintenance is minimal.

  • Sensor flexibility – Works with standard proximity probes and accelerometers many plants already stock.

  • Global support ecosystem – Bently Nevada hardware is widely used, making spare parts and field knowledge easier to source.

Installation & Maintenance
  • Panel/Cabinet – Mount in a clean, ventilated enclosure with adequate depth for field wiring. Avoid high‑heat zones and strong EMI sources.

  • Power & Grounding – Use a clean 24 VDC source; bond shields at a single point and maintain good cabinet grounding practices.

  • Transducer wiring – Route proximity/accelerometer and Keyphasor® cables away from high‑voltage lines; maintain correct polarity and shielding.

  • Alarms & Logic – Set Alert/Danger thresholds based on actual baseline data. In many cases, a short time delay reduces false trips on start‑ups.

  • Routine checks – Periodically verify 4–20 mA scaling, exercise relays, and review alarm logs. Clean terminals and tighten screws during shutdown windows.

  • Firmware/config – Keep configurations backed up; apply manufacturer‑approved firmware updates when available.

Quality & Certifications
  • CE compliant

  • UL/cUL approvals (model‑dependent)

  • RoHS compliant

  • Manufactured under ISO 9001 quality systems

  • Manufacturer’s warranty applies; we provide a 365‑day warranty on supply

Quick Tip

If you’re replacing legacy monitors, keep the existing probe types in mind. The 1900/65A typically accepts standard proximitor and accelerometer signals, so reuse is often possible—saves time and reduces spares complexity.

Product Tags: 1900/65A-00-04-01-00-00 , Bently Nevada 1900/65A-00-04-01-00-00 , Bently Nevada 1900

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Trading Company
Year Established
2014
Annual Export Value
US$2.5 Million - US$5 Million
Total Employees
51 - 100 People

Recommended Categories

Explore top categories and find suppliers for your specific needs