Bently Nevada 1900/65A-00-04-01-00-00 – General Purpose Equipment Monitor for Reliable Machinery Protection
Warranty: 365 days
Delivery: 1 week if in stock; no more than 1 month latest
Payment Terms: 50% advance; full payment before delivery
Express Options: FedEx, UPS, DHL
Two dynamic channels – Typically configured for proximity probes or accelerometers to monitor vibration on balance-of-plant equipment.
Keyphasor®/tach input – Supports speed and phase reference, enabling 1× tracking and more meaningful alarms.
4–20 mA outputs – Proportional outputs per channel for easy tie-in to PLCs/DCS; keeps operations teams informed without extra software.
Dual-level alarms (Alert/Danger) – Standard protection philosophy with configurable latching and time delays in many cases.
Relay outputs – Use as annunciation or for interlocks/trips on exceedance; simplifies protection design.
Modbus communications – Typically Modbus RTU over RS‑485 for status, values, and health—handy for remote supervision.
Compact installation – A space‑saving monitor that fits into crowded MCCs or local junction cabinets.
Configured for general-purpose assets – Suits pumps, fans, and blowers where continuous protection is desired without a full rack system.
| Brand / Model | Bently Nevada 1900/65A-00-04-01-00-00 (General Purpose Equipment Monitor) |
| HS Code | 9032.89 (Automatic regulating or controlling instruments and apparatus) |
| Power Requirements | 24 VDC nominal |
| Signal Inputs | Two dynamic vibration channels (proximity or accelerometer); Keyphasor®/tach input |
| Signal Outputs | 4–20 mA proportional outputs; alarm/trip relays (form C) |
| Communication Interfaces | Modbus RTU (RS‑485) |
| Installation Method | Compact cabinet mounting; commonly DIN‑rail in many panels |
This monitor is typically specified for balance‑of‑plant rotating assets across:
Oil & Gas and Petrochemical – auxiliary pumps, blowers, air coolers
Power Generation – condensate/extraction pumps, ID/FD fans, cooling tower gearboxes
Water & Wastewater – high‑service pumps and aeration blowers
Pulp & Paper / Mining – process fans, slurry pumps, vacuum pumps
General Industry – HVAC chillers, compressors, and utility machinery
A maintenance lead from a midstream facility told us it “dropped nicely into our existing PLC cabinet, 4–20 mA into the DCS, and the relays tied straight into the trip logic—no drama, and we got legitimate alarm points rather than guesswork.”
Reliable protection – Dual-level alarms and hardwired relays reduce nuisance trips while still guarding the asset.
Easy integration – 4–20 mA and Modbus RTU mean fast commissioning into almost any PLC/DCS without special software.
Lower lifecycle cost – A compact monitor usually costs less than a full rack, and ongoing maintenance is minimal.
Sensor flexibility – Works with standard proximity probes and accelerometers many plants already stock.
Global support ecosystem – Bently Nevada hardware is widely used, making spare parts and field knowledge easier to source.
Panel/Cabinet – Mount in a clean, ventilated enclosure with adequate depth for field wiring. Avoid high‑heat zones and strong EMI sources.
Power & Grounding – Use a clean 24 VDC source; bond shields at a single point and maintain good cabinet grounding practices.
Transducer wiring – Route proximity/accelerometer and Keyphasor® cables away from high‑voltage lines; maintain correct polarity and shielding.
Alarms & Logic – Set Alert/Danger thresholds based on actual baseline data. In many cases, a short time delay reduces false trips on start‑ups.
Routine checks – Periodically verify 4–20 mA scaling, exercise relays, and review alarm logs. Clean terminals and tighten screws during shutdown windows.
Firmware/config – Keep configurations backed up; apply manufacturer‑approved firmware updates when available.
CE compliant
UL/cUL approvals (model‑dependent)
RoHS compliant
Manufactured under ISO 9001 quality systems
Manufacturer’s warranty applies; we provide a 365‑day warranty on supply
If you’re replacing legacy monitors, keep the existing probe types in mind. The 1900/65A typically accepts standard proximitor and accelerometer signals, so reuse is often possible—saves time and reduces spares complexity.
Send Inquiry to This Supplier
You May Also Like
-
Bently Nevada 330106-05-30-90-02-CN – 3300 XL 8 mm Reverse-Mount Probe for Space‑Limited MachineryUS$ 2216.00MOQ: 1 Blade
-
Bently Nevada 330104-00-06-10-02-00 Proximity Probe – Cost‑Effective 8 mm Eddy-Current Sensing for Budget-Conscious ProjectsUS$ 216.00MOQ: 1 Blade
-
Bently Nevada 330104-00-04-10-02-05 Proximity Probe – 3300 XL 8 mm Sensing for Shaft Vibration and PositionUS$ 216.00MOQ: 1 Blade
-
Bently Nevada 330104-00-13-10-02-05 – 3300 XL 8 mm Proximity Probe for Reliable Shaft Vibration & Position MonitoringUS$ 216.00MOQ: 1 Blade
-
Bently Nevada 3300 XL 8 mm 330104-00-04-10-02-00 – Proximity Probe for Critical Rotating MachineryUS$ 216.00MOQ: 1 Blade
-
Bently Nevada 330906-02-12-05-02-CN 3300 NSv Reverse Mount Probe – Compact Eddy-current Sensing for Tight Spaces and Small Shaft TargetsUS$ 216.00MOQ: 1 Blade
-
Bently Nevada 330710-000-60-10-02-00 – 3300 XL 11 mm Proximity Probe for Machinery ProtectionUS$ 1216.00MOQ: 1 Blade
-
Bently Nevada 330103-12-18-05-02-00 – 3300 XL 8 mm Proximity Probe for Fast, Reliable SetupUS$ 216.00MOQ: 1 Blade
-
Bently Nevada 330709-000-050-10-02-00 | 3300 XL 11 mm Proximity Probe for Harsh ConditionsUS$ 216.00MOQ: 1 Blade
-
BENTLY NEVADA 3500/72M – Dual‑Channel Vibration Monitoring Module for Critical Machine ProtectionUS$ 3216.00MOQ: 1 Blade