Home > Electrical & Electronics > Inverter > Power Inverter > SKN-S Pure Sine Wave Inverter 1-6KW

SKN-S Pure Sine Wave Inverter 1-6KW

SKN-S Pure Sine Wave Inverter 1-6KW photo-1
SKN-S Pure Sine Wave Inverter 1-6KW photo-2
SKN-S Pure Sine Wave Inverter 1-6KW photo-3
SKN-S Pure Sine Wave Inverter 1-6KW photo-4
SKN-S Pure Sine Wave Inverter 1-6KW photo-5
SKN-S Pure Sine Wave Inverter 1-6KW photo-6
US$ 100 - 500 MOQ: 1 Unit
Key Specifications
Get Latest Price
Place of Origin:
Guangdong, China
Brand Name:
SAKO
Model Number:
SKN-S 1-6KW
Payment & Shipping
Payment Methods:
Port of Shipment:
shenzhen
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Guangdong, China
Brand Name SAKO
Model Number SKN-S 1-6KW
Output Power Other, >1000W
Output Type Single
Size 438*184*181mm
Weight 1000VA:16.5kgs
Input Voltage 110V or 220V
Output Voltage 110V or 220V
Type DC/AC Inverters
Output Frequency 50/60Hz
Output Current 5-30A
0, 0, 22, 5, 0, 166, 23, 18
MODEL
SKN-S 1KW SKN-S 2KW SKN-S 3KW SKN-S 4KW SKN-S 5KW SKN-S 6KW
SPECIFICATION
DC INPUT
Input Voltage(Vdc) 12V/24V 24V/48V
Min DC start voltage(Vdc) 10V/20V 20V/40V
AC Bypass 
Nominal Input Voltage 110V or 230Vac(waveform:Sine or generator)
Input AC Range(Vac) 90Vac±4%-135Vac±4% or 184Vac±4%-253Vac±4%
Frequency Range(HZ) 57Hz or 60Hz(47Hz -53Hz for 50Hz)-----{57Hz -63Hz for 60Hz}
Input Frequency(Hz) 50Hz/ 60Hz  (Auto detection)
Bypass Output Voltage(Vac) same as input voltage
Bypass Output Frequency(Hz) same as input frequency
Pass through without Battery Yes
Max Bypass Overload Current 30A
AC  Efficiency > 95%
Transfer Time(ms) 20ms (typical) 
CHARGER
Charge mode Input Voltage Range 95~127Vac or 196~243Vac
Automatic Charge mode Three stage charge mode:Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage)
Nominal Charge Voltage According to the battery type setup
Charge Current(A) 17.5A/35A/70A
Charge boost voltage(v) According to the battery type setup( 12V BAT:14-15.5v   24V BAT:   28-31V   48V BAT:56-62V )  
Charge Floating Voltage(V) According to the battery type setup (12V BAT: 13.3-13.7,  24v BAT: 26.6-27.6,  48V BAT:53.2-55.2V)
Over Charge Protection Bat. V ≥15.7Vdc, beeps 0.5s every 1s & fault after 60s (15.7 for 12v,  31.4V for 24V,  62.8V for 48V)
Charger Short Circuit Protection Circuit breaker
(INVERTER)
Capacity(VA) 1000 2000 3000 4000 5000 6000
Output Power(W) 1000 2000 3000 4000 5000 6000
Power Factor(PF) 1
Output Voltage 120VAC or 230VAC  (Sine wave)
Output Frequency 50/60 ± 0.3Hz(auto tracking main first power connection)
Wave   pure sine wave
Inversion Efficiency >88%
Over load capacity (110%<load<125%) ±10%: Fault (shutdown output) after 15 minutes;
(125%<load<150%) ±10%: Fault (shutdown output) after 60s;
Load>150% ±10%:  Fault (shutdown output) after 20s
Low Battery Alarm 10.5Vdc ± 0.3Vdc for 12V battery,  21.0Vdc ± 0.6Vdc for 24V battery,  42.0Vdc ± 1.2Vdc for 48V battery
Power saver Load less than 25W (Enabled on “P/S auto” setting of Remote control)
AMBIENT
Noise(dB) 60dB max
Temperature 0°C to 40°C
Humidity 5% to 95%
Sea Level(m) <=1500
DIMENSION
Product size  L×W×H(mm) L438mm*W184mm*H181mm L608:mm*W184mm*H181mm
Packing size L590*W312*H295mm L808*W360*H352mm
Weight(Kg) 16.5/17.5 19/20 24/25 34/37 38.5/41.5 44.5/47.5

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
1997
Factory Size
10,000-30,000 square meters
Total Employees
101 - 200 People

Recommended Categories

Explore top categories and find suppliers for your specific needs