Arc Fault Circuit Interrupter (AFCI) is the latest circuit protection product. Its main function is to detect and identify dangerous earthing arc faults, parallel arc faults and series arc faults, and to drive the device operation that cut off current timely to avoid electrical fires. When arc fault occurs, due to the low current intensity, lower than setting values of overcurrent protection which are installed in power system, especially widely in low-voltage distribution field, installing AFCI in the distribution line terminal can promptly find the arc and cut off the circuit, effectively reduce the damage caused by the arc.
Fault arc circuit breaker is an intelligent circuit protector, integrated design of MCB and RCCB, which can detect and identify faulted arcs and normal operating arcs in the circuit. Prevent the fire hazard caused by the arcing faults such as poor contact and bad insulation in the electric circuit. Set fault arc protection, overload protection, short circuit protection, overvoltage protection, surge suppression, leakage protection into one.
TXAFCI-63 Arc Fault Circuit Interrupter AFDD Fault Arc Detector Circuit Breaker
AFCI Arc Fault Circuit Interrupters are mainly installed in the distribution box of the terminal distribution system, can also be installed in the home, office, all kinds of large supermarkets, department stores, hospitals, airports, textile mills, warehouses, oil depots, refineries, entertainment places, hotels, oil transport pipelines and other occasions, Where there is electricity, the devices can be installed and used, widely used in electrical fire prevention.
Use the fault arc comprehensive detection method combined with line current time domain and frequency domain FFT to realize the simultaneous positioning of the time domain and the frequency domain.
● Its features are as follows:
(1) With automatic control and manual control function;
(2) With the function that detect and identify dangerous ground arc fault, parallel arc fault and series arc fault;
(3) With the function that timely drive device action to cut off the current to avoid the electrical fire;
(4) With detection of overcurrent, short circuit, overvoltage and many other features;
(5) With fault memory function, easy to fault query, analysis.
(6) With indicator light alarm function
(7) With a number of rated current, voltage
(8) With single pole rated on and off function
(9) With the function of displaying the fault result
(10) With free trip function
(11) With the functions of rust prevention, humidity resistance and electric shock protection
● With the characteristics of self matching between control and protection compared with the system consisting of discrete components
AFDD set control and protection function in one, equivalent to arc detector identifier + circuit breaker. Which solves the matching problem of the protection and control characteristics of the discrete components, so that the protection and control characteristics can be more perfect.
● Compared with the circuit breaker and the fuse, has the characteristics of arc detection and protection
The conventional short-circuit protection mechanism based on circuit breakers and fuses can only meet the function protection of the equipment when the short-circuit capacity is very small. When arc fault occurs, due to the low current intensity, lower than setting values of overcurrent protection which are installed in power system, especially widely in low-voltage distribution field, therefore can not fully protect against arc faults.
● With comprehensive inspection compared to arc detection device of sensor
When detect the arc parameters via sensors, it must be installed in the location of the fault arc, which brings inconvenience to comprehensive inspection in the circuit, and AFDD solves this problem very well.
● With real-time compared with residual current protector (RCD)
When series and parallel arc fault occur, the fault impedance reduces the load current, making the current lower than the RCD trip value, resulting in RCD can not trip quickly in real time.
● The technical improvement for the electromagnetic mechanism, materials and technology and electronic circuits are processed, to avoid the heat, too high temperature caused by long time work of electromagnet, greatly reduce the electromagnet operating temperature, thereby enhancing the service life.
● Suitable for all types of loads, high stability.
● Rated operational current of arc fault circuit breaker is up to 63A.
● Use high-performance single-chip system for the system design, to achieve digital control.
● Special electromagnetic tripping mechanism, greatly improving the accuracy of overcurrent protection.
● When arc faults occur, multiple judgments are made within the MCU. When all the features are matched, the trip will be performed.
● The products can be used in a wide range, households, enterprises, hospitals, schools and research institutions.
● Integration: Short circuit protection, leakage protection, arc protection combined into one
● Stable: does not affect the detection capability due to shield of suppression load or EMI load
● Multi-domain detection: time domain, frequency domain
● Flexible installation: plug-in type, bolt type, rail type installation.
● Power supply module: Power supply to related devices in AFDD (arc fault detection device).
● Signal conditioning module: Through current transformer, the current signal in the main circuit is amplified, rectified and filtered through the signal conditioning module, and then sent to the microcontroller.
● Release module: In the AFCI, the electromagnetic structure of the release module use new energy-saving technology, the core loss and short circuit loss of the switch electromagnetic system are minimized, saves power to the greatest extent. Add the buffer device to reduce the energy impact of the electromagnetic system, to improve the pull in performance of the switch and prolong the service life. The operation mechanism of the release module can receive the fault signal detected by the MCU, cut off the coil circuit by controlling contacts, and break the main circuit by the electromagnetic mechanism. After troubleshooting, press the operation button to reset.
● Communication interface module: Through this module, the current, voltage, current phase, arc signal and other data can be transmitted to the terminal computer in real time, and the remote monitoring can be realized. The following is the current data information that MCU sends the data information to the host computer when the series arc occurs. Data processing module uses dedicated AFDD host computer development platform of independent research and development for data analysis and feature parameter extraction. Establish PC simulator, the algorithm is pre simulated on the PC end, executive language and microprocessor are in common use.
The main control chip MCU of the AFCI real-time detects the current signal in the main circuit. When the fault arc is detected in the main circuit, the single chip microcomputer sends out the tripping signal, and the tripping circuit implements the tripping operation.
Overload and other protection: When the main control chip MCU of the AFCI will real-time detect of overload, leakage, undervoltage, overvoltage, overcurrent and other faults in the main circuit, send fault signal to the release, break the circuit, realize the protection operation.
• LED lights (green/red/yellow) indication: overload, leakage, overvoltage, undervoltage, short circuit, AFDD arc fault alarm;
• Can be mounted on the standard busbar;
• Dual-Use Terminals (Lift/Open) on upper/lower side;
• Busbar positioning of upper or lower is optional;
• When installed in the bus bar, the terminal space is large and can be removed independently;
• Safety connection instructions;
• The rated current indicated by the color switch (MCB component);
• Perfect accessories for subsequent installations;
• Test key "T" must be pressed once every year;
The system operator must be notified of this responsibility requirement in a provable manner. Under special conditions (for example, in wet and/or dry environments, in a polluted and / or corrosive environment, in environments with large temperature fluctuations, a device that causes overvoltage risk due to switching equipment and / or atmospheric discharge, hand-held equipment, etc.), it is recommended to be tested once a month. If the red and yellow LEDs flash alternately, further testing is required;
• Press the test key "T" to use only for functional testing of the RCD. This test does not measure grounding resistance (RE), nor does it perform redundant inspections of grounded conductors. These tests must be performed separately;
• Model A: protection against special non-smooth pulsating DC residual currents;
• Li/A protects the special form of non-smooth pulsed DC residual current with a certain delay to prevent accidental tripping.
Meet GB/T11681-2013 Standard
1. Limit value of break time of AFDD (Arc Fault Detection Device) at the rated voltage of 220V is shown in table
2.Residual current breaking time of residual current circuit breaker is shown in table
Test button: Used to test the leakage function of AFCI, press the "T" test button, AFCI is broken, otherwise regarded as normal.
Handle: Used to turn on and off the circuit. Pull the handle to the ON position to turn on the circuit, OFF position to turn off the circuit.
◆ Operating Instructions
Place the AFCI handle in the OFF position to properly access the circuit.
Place the AFCI handle in the ON position and turn on the circuit.
Arc test: Press the test button and AFDD trip, it is normal. If not normal, please replace.
Place the AFCI handle in the ON position and turn on the circuit.
◆ LED Instructions
See the normal work of LED circuit on the basic wiring diagram, green light on, red light off. If the red light is on, it indicates that there is a problem in the self-check process of AFDD. Restart AFCI, if the above situation still occurs, please replace AFCI.
1. The leakage, overload and protection characteristics of Arc Fault Circuit Interrupter are made by manufacturers, the users can install directly, can not open the back cover to adjust at will.
2. The function of the test button of Arc Fault Circuit Interrupter: When installing , press the button in the connecting state or after running for a certain period of time, press the test button once a month, check whether the leakage protection is reliable. When in the ON state, green light on, red light off; After press the leakage test button, the release trip, show that the AFCI is normal, otherwise the AFDD is bad, get a new to use.
3. Arc Fault Circuit Interrupter is broken due to the protection circuit failure (circuit arc, poor contact, line breakage, leakage, over-current, overload, short-circuit), should identify the reasons, the AFCI handle is placed in the ON position after troubleshooting, connected to the circuit.
4. See the basic wiring diagram: This product does not allow the power to enter from the output.
5. Arc Fault Circuit Interrupter do not protect electric shock risk caused by contacting with two lines of the protective circuit at the same time.
6. Wiring see the basic wiring diagram: When wiring, the incoming line and outgoing line must pay attention to the installation method of left null line and right live wire, while ensuring that the terminal must be pressed.
/p2/15-20-30-Amp-AFCI-Circuit-Breaker-Arc-Fault-Detection-Devices
Send Inquiry to This Supplier
You May Also Like
-
DW45 Air Circuit BreakerUS$ 450 - 600MOQ: 1 Piece
-
TXAFCI-63 Arc Fault Circuit Interrupter AFDD Fault Arc Detector Circuit BreakerUS$ 80 - 100MOQ: 1 Piece
-
Safe HT-63 Arc Fault Circuit Interrupter AFDD Fault Arc Detector Circuit BreakerUS$ 55 - 60MOQ: 1 Piece
-
Current Limiting Fuse RW11-12KV, for High and Low Fault Current InterruptionUS$ 25MOQ: 10 Units
-
Brand New Siemens Circuit Breaker Arc Fault Breaker Siemens 3RV1011-1FA10 in StockNegotiableMOQ: 1
-
7XG3124-1AB00-0AA0︱Siemens RA24 Arc Fault MonitorUS$ 7200 - 7632MOQ: 1 Unit
-
Spot‑Available Keysight DSOX1202A Bench Oscilloscope High‑Sampling‑Rate Circuit‑Fault TesterNegotiableMOQ: 1 Unit
-
2012 New Ground Fault Circuit InterrupterUS$ 4 - 10MOQ: 100 Pieces
-
Receptacle Ground Fault Circuit Interrupt Factory for Ground Fault Circuit Interrupter Safety Products With USB Slot NANDAO ElecUS$ 5 - 5.5MOQ: 10 Pieces
-
Ground Fault Circuit Interrupter Gfci Electrical SocketsUS$ 1 - 30MOQ: 150 Sets