PV1-F
Product Spotlights
Application
Solar cables PV1-F acc. to 2 PfG 1169/08, are intended for use in Photovoltaic Power Supply Systems at nominal voltage rate up to 1,8kV D.C.
They are suitable for applications indoor and/or outdoor, in industrial and agriculture fields, in/at equipment with protective insulation (Protecting Class II), in explosion hazard areas. They may be installed fixed, freely suspended or free movable, in cable trays, conduits, on and in walls.
Construction
● Conductor: Flexible tinned copper class 5 (K) as per IEC 60228
● Insulation: Halogen - free cross - linked LS0H - XL compound, black
● Outer sheath: Halogen - free cross - linked LS0H - XL compound, black or red
Characteristics
● Rated voltage
D.C.: 1,0 kV
A.C.: 0,6/1,0 kV
● Max. permissible operating voltage:
D.C.: 1,8 kV
A.C.: 1,2 kV
● Test voltage
A.C.: 6,5 kV/5 min
D.C.: 15 kV/5 min
● Minimum bending radius Fixed installation approx. 4 x outer diameters
●Temperature range Operating temperature: -40°C to +90°C Max. conductor temperature: 120°C
Specification
2 PfG 1169/08 Requirements for Cables for Use in Photovoltaic - Systems
High reliability
Super high pressure
Less maintenance
Technical Parameter
2 PfG 1169/08
| No. of Cores and Nominal Cross Section | Max. Diameter of Copper Wires |
Min. Insulation Thickness |
Min. Sheath Thickness | Approx. Weight |
Max. D.C. Resistance of Conductor at 20℃ |
| No.× mm² | mm | mm | mm | kg/km | Ω/km |
| 1×1.5 | 0.26 | 0.5 | 0.5 | 32 | 13.7 |
| 1×2.5 | 0.26 | 0.5 | 0.5 | 43 | 8.21 |
| 1×4 | 0.31 | 0.5 | 0.5 | 56 | 5.09 |
| 1×6 | 0.31 | 0.5 | 0.5 | 79 | 3.39 |
| 1×10 | 0.41 | 0.5 | 0.5 | 128 | 1.95 |
| 1×16 | 0.41 | 0.5 | 0.5 | 186 | 1.24 |
| 1×25 | 0.41 | 0.5 | 0.5 | 284 | 0.795 |
| 1×35 | 0.41 | 0.5 | 0.5 | 384 | 0.565 |
| Current rating conversion factors for different ambient temperatures | ||||||
| Ambient Temperature,℃ | Up to 60 | 70 | 80 | 90 | 100 | 110 |
| Conversion Factor | 1.00 | 0.91 | 0.82 | 0.71 | 0.58 | 0.41 |
| Nominal cross section | Current carrying capacity | ||
| Single cable, in air | Single cable on a surface |
Two loaded cables touching, on a surface | |
| mm² | A | A | A |
| 1.5 | 30 | 29 | 24 |
| 2.5 | 41 | 39 | 33 |
| 4 | 55 | 52 | 44 |
| 6 | 70 | 67 | 57 |
| 10 | 98 | 93 | 79 |
| 16 | 132 | 125 | 107 |
| 25 | 176 | 167 | 142 |
| 35 | 218 | 207 | 176 |
Ambient temperature: 60℃,Maximum conductor temperature: 120℃.
Send Inquiry to This Supplier
You May Also Like
-
XHHW-2 ALUMINUM CONDUCTORNegotiableMOQ: 3000 Meters
-
RHH/RHW-2/USE-2 ALUMINUM CONDUCTORNegotiableMOQ: 3000 Meters
-
H07V-U (BV)NegotiableMOQ: 3000 Meters
-
H07V-R (BVR)NegotiableMOQ: 3000 Meters
-
H07V-K (RV)NegotiableMOQ: 3000 Meters
-
Rated Voltage 0.6/1 kV Reel Cable for Drilling RigsNegotiableMOQ: 3000 Meters
-
Rubber Insulation Cables And WiresNegotiableMOQ: 3000 Meters
-
MC-XHHW-2 ALUMINUM (AA-8000)NegotiableMOQ: 3000 Meters
-
TECK90 INTERLOCKED ARMOUR CABLESNegotiableMOQ: 3000 Meters
-
600V Service CableNegotiableMOQ: 3000 Meters