CE Medical Oxygen Regulator(DY-C3)A
Specifications
Medical oxygen Regulator
Input Pressure:15mpa
Output Pressure:0.2mpa-0.3mpa
Control Pressure of Safety Valve:0.35±0.05mpa
Details Description of Medical Regulator
Gas Type:oxygen
Input Pressure:15mpa
Outout Pressure: 0.2mpa-0.3mpa
Fowmete Control Range :1L/min-10L/15L/min
Material:breass
Connecting therad:Female G:5/8
Mainbody:Copper
Structure:piston type
Packing:10PCS/CTN(Color box)
GW/NW:19.2kg/18.2kg
Dimension:56*41*17.5cm
Main Feature
1.The product has artistic outlook,and flow control comfortable and stable .
2.The intemational standard connect way,is suitable for all kinds of gas bottle installation
Range of application
Give oxygen for first-aid or oxygen uptake for the penpie who are lack of oxygen
How to use
1.Open the valve of oxygen cylinder after connect the screw screw nut of air intake closely
2.Connect the oxygen pipe to the oxygen outlet firmly
3.Demount the humidifying cup (anti clock wise rotation)put some distilled water in (puried water or plain boiled water can also take place),the wate aqahtity should be bottom and top tick mark,then tighte up the bottle cap to the humidifying cup (clokwise rotation).
Applications
Medical Regulator wide range of therapeutic use in hospital clinics,home care emergency units and so on.
How to use
1. Open the valve of oxygen cylinder after connect the screw nut of air intake closely.
2. Connect the oxygen pipe to the oxygen outlet firmly.
3. Demount the humidifying cup(anti clock wise rotation), put some distilled water in (purified water or plain boiled water can also take place), the water quantity should be between the bottom and top tick mark, then tighten up the bottle cap to the humidifying cup(clockwise rotation).
4. Rotate the flow regulating valve to the rate you need (anti clockwise to up, clockwise to down, till to close), then put it to nose to use.
5. Close the valve of oxygen cylinder firstly while not using, then close the flow regulating valve until the pointer of oxygen manometer return to zero.
Attention
1. Make sure there is no ash on the connector and check the screw thread, then install the inhalator.
2. Make sure the flow meter is vertical to the floor and flow regulating valve is closed, then open the valve of oxygen cylinder slowly, regulate the flow after the high pressure gauge shows the pressure of the oxygen cylinder.
3. No drastic shock, far away with the corrosive substance, and no oil stain.
4. The set screw of the safety valve can't be rotated at random, non-professional people are forbidden to dismount.
Condition for storage
Should be kept in the environment whose humidity is less than 90%, no corrosive gas and drafty.
Quality guarantee period
We will fix or change the oxygen inhalator within a half and a year after the day of living the company when it can't proper functioning, it should be under the condition of obeying the rule of storage and using.
Send Inquiry to This Supplier
You May Also Like
-
Static Pass Box(passing Box & Equipment for Clean Room)NegotiableMOQ: 1
-
High Quality Hydraulic Obstetric Delivery Surgical Table Manual Birthing ChildbedNegotiableMOQ: 1 Set
-
Quick Release Basket Ambulance Stretcher Band/strap/beltNegotiableMOQ: 300 Pieces
-
26 Pcs First Aid Kit,Car Emergency Kit,auto Safety KitNegotiableMOQ: 1000 Sets
-
First AidUS$ 0.5 - 0.5MOQ: 5000 Pieces
-
Emergency Blanket/Emergency Membrane/Rescue BlanketsNegotiableMOQ: 1000 Pieces
-
Plastic Aid Board by RotomouldedNegotiableMOQ: 1
-
Expert Supplier of Suction MachineUS$ 2,300 - 6,900MOQ: 1 Set
-
Shoulder Joint-functional Model Half Life SizeNegotiableMOQ: 50 Pieces
-
(KL600-II) Integral Single Head Wall Mounted OT Lights Led ot Lights Medical ot LightsUS$ 1,400 - 1,600MOQ: 1 Set