Home > Electrical & Electronics > Power Transmission & Transformer > Transformer > PDF3000DC System Earth Fault Detector

PDF3000DC System Earth Fault Detector

PDF3000DC System Earth Fault Detector photo-1
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Brand Name:
GDMK
Place of Origin:
China
Model Number:
PDF3000
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Brand Name GDMK
Place of Origin China
Model Number PDF3000
Product Introduction

DC system grounding fault tester  is a new generation of tester. It can be applied to dc systems of any voltage grade. It is equipped with high-precision detection clamp table which greatly improves the detection range and anti-interference ability through efficient processing of multiple signals. Advanced algorithm and fuzzy control theory are adopted to express the superiority degree of detected insulation branch in numerical form which fully reflects the superiority of artificial intelligence. They have accurate judgment on the location of the grounding point and can point out the location and direction of the grounding point every time.

DC system grounding fault tester takes system safety as the primary premise conducts detection in a reliable low-frequency signal in strict accordance with the requirements of industry standards and carries out a large number of practical applications in the field without any impact on the system.

Dc systems in power plants and substations provide power supply for control protection signals and automatic devices. The safe and continuous operation of dc systems is of great importance to ensure power supply and distribution. As the dc system is not grounded by floating system if two-point grounding occurs it may cause the above devices to misoperate and refuse to operate thus causing a major accident. Therefore when one point grounding occurs the grounding point should be accurately and quickly detected while ensuring the normal power supply of the dc system to eliminate the grounding fault so as to avoid the possible harm of two points grounding.

DC system grounding fault tester is used to find the exact location of DC system grounding points of power plants and substations in the case of constant electricity. All kinds of grounding faults can be found out quickly with good accuracy.

Product nickname: DC Ground Fault Tester DC System Fault Tester DC System Ground Fault Tester DC System Ground Fault Tester

Product Characteristics Product Characteristics
  • 1、It is simple to use. The DC System Ground Fault Tester can be used directly by turning on the power supply switch without any other keys operation.

  • 2、Safe and reliable DC System Ground Fault Tester does not need to stop floating charger and all other power supply which has no impact on the DC System.

  • 3、Applicable voltage levels dc system 220V 110V 48V 24V can be used.

  • 4、Wide range of application any type of power plants substations coal mines chemical plants and other power supply departments can be used.

  • 5、Easy to carry the signal receiver with its own battery no external power supply can be carried to any place to find the location.

  • 6、Dc system constantly looking for the receiving site does not affect the normal work of the system.

  • 7、Strong anti-interference ability overcomes the influence of distributed capacitance.

  • 8、Intelligent charging management can reduce charging time and extend battery life.

  •  

Product Parameters
Technical parameters
Signal generator output signal frequency 2.5Hz
signal no-load output voltagee ±20V±5%
signal voltage amplitude error
signal short circuit output current ≤80mA
impact resistance of output port 400V dc impact
power supply voltage AC220V±10%
voltage frequency 50Hz±5%
input insurance 200mA
maximum power 3W
volume 300×270×200mm3
Signal receiver signal current detection sensitivity 0.5mA
signal generator impedance 40KΩ
maximum output current 2.5 mA
receiver displays digits0~19
volume 210×100×32mm3
aclamp size Φ50mm
bclamp size Φ7mm×9mm
Complete machine detection maximum ground resistance 300kΩ
ground resistance measurement accuracy

0~4.5kΩ,error≤0.5kΩ

4.5kΩ~300kΩ,error≤10%

External dimension( mainframe) 340*290*140mm3
Weight ( mainframe) 3.96kg
External dimension 390*290*140mm3
Weight 2.8kg


Product Tags: DC Ground Fault Tester , DC System Fault Tester

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Manufacturer
Year Established
2014
Main Markets
Southeast Asia

Recommended Categories

Explore top categories and find suppliers for your specific needs